Edmonton Power History Foundation Blog

Results: 41 to 50 of 67

Disconnect Switch

1922 Disconnect Switches are used to isolate an electrical circuits



Disconnect Switches are used to isolate an electrical circuits Specifications Manufacturer:  Canadian Westinghouse Voltage 15000 Amp 600 Style No H.14309 Pat 1922 Manufacturer: Electrical Engineers Equipment Co. Voltage 4000 Amp 300 Style Cat 17101 ...

read more

Vintage Electric Meter Display

Polyphase Kilowatt Hour Meter (sidebar)



Floor display of vintage commercial/industrial/residential Watt Hour, VAR, Voltmeters, Ammeters, Consumption, 3 Phase, 1 Phase revenue meters, manufactured by Sangamo, GE, Westinghouse, Reyrolle, Weston,

read more

Categories: Instruments Collection
Tags: Meters

Turbine Blades

Several blades from Rossdale No. 8 Turbine



This shows how the size of the blades increases to handle the larger volume of steam as it expands while traveling thru the turbine

read more

Hydrogen Panel Display

This panel was built to simulate the hydrogen cabinet used on No. 9 and 10 Parsons generators



The cabinet was used to control the cooling medium (hydrogen) within the Generator Consisted of 4 Gauges for: Hydrogen Temperature Seal oil pressure Hydrogen Pressure Carbon Dioxide Pressure Alarm panel Hydrogen Purity Meter Flow Meter AC and DC seal ...

read more

Boiler Wall Tubes Circa 1970s

Section of boiler wall from Clover Bar



This is a section of furnace wall tubes; this type is known as a membrane wall as the furnace is pressurized. Below is a section of Clover Bar No. 4 boiler wall being cut out during demolition (January 19, 2007): Manufacturer Babcock and ...

read more

Categories: Boilers Collection
Tags: Clover Bar

Model of Rossdale Low Pressure Plant

Circa 1990



Showing; Boiler house, Turbine hall and Electrical Switching stationModel was built by the NAIT Architectural Technology Students

read more

Solid State Rectifier Reliance

Circa 1985



Used to Convert Alternating Current to Direct Current From the Edmonton 360 Sub 104 St. x 104 Ave. Supplied DC power for the operation of Edmonton's trolley Buses

read more

Categories: Rectifiers Collection

Solid State Rectifier GE

Circa 1964



Used to Convert Alternating Current to Direct Current From the Edmonton Transit system Supplied DC power for the operation of Edmonton's trolley Buses. Came from Man and His World  Montreal Expo 67 Installed in 1978-9 at the Westwood bus barn ...

read more

Categories: Rectifiers Collection

Direct Current Rectifier Panel

Circa 1936 this Panel was utilized in the operation of Edmonton's trolley Buses




read more

Impedance Bridge

Circa 1960's



Impedance bridge theory developed in 1830's and in the 1840's Charles Wheatstone improved it for accurate resistive/impedance testing. Note "magic eye" tube lower center.

read more

Categories: Instruments Collection

Edmonton Power Historical Foundation

Location: 

We are located on the grounds of the Leduc West Antique Museum. Travel 5 km west of Leduc on Highway 39. Go north on Range Road 260 (Cohne Dale Road) for about 800 metres and the museum will be on your right. If you're coming from the west, Cohne Dale Road is 5km east of Highway 60.

Hours of operation 2026

On September 19, after a very succesful Lesco Truck Show, we closed our doors and shuttered our windows, as the 2026 season ended and winter began it's inexorable approach. The Edmonton Power Historical Foundation Museum may be closed, but the the Leduc Country Lights will be coming to the Leduc West Antique Society park. For the entire month of December the park will be lit with thousands of festive lights creating a magical winter wonderland that is an absolute joy to behold! Bring the whole family and wander in wonder at this amazing display.

Our 2027 dates will be published here as soon as they are annonced. We hope to see you in the spring!

 

 

Leave us a message

 
 
Top